Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Kinase, Sakae; Noguchi, Hiroshi; Sakamoto, Yukio; Nakamura, Takashi*; Kimura, Masaya*
Proceedings of 1st Asian and Oceanic Congress for Radiation Protection (AOCRP-1) (CD-ROM), 10 Pages, 2002/10
It is necessary to develop suitable tissue substitutes for the respiratory tract phantom. In the present study, optimum amounts of additive in the base materials were calculated in accordance with the basic data method. On the basis of the method, tissue substitutes with high mass density were made on an experimental basis. The substitutes were examined for the photon transmissions using 16.6 keV K-Xrays from Nb-93m and 59.5 keV gamma-rays from Am-241. It was found that the experimental transmission curves of the tissue substitutes are in good agreement with the calculated ones. Furthermore, mass attenuation coefficients for the tissue substitutes of the JAERI torso phantom were evaluated. It was found that the tissue substitutes are suitable as phantom materials and can simulate the body tissues defined in ICRP Publication.23.
Oishi, Tetsuya; Tsutsumi, Masahiro; Sugita, Takeshi*; Yoshida, Makoto
Proceedings of 1st Asian and Oceanic Congress for Radiation Protection (AOCRP-1) (CD-ROM), 9 Pages, 2002/10
An EGS4 user code has been developed to design gamma ray detection systems for complex shapes of radioactive sources. The code is fundamentally based on the PRESTA-CG, which is improved on the electron transport in the EGS4 and specialized for using a combinatorial geometry (CG) method. The newly added functions are classified mainly into two parts of the transport of particles and the definition of sources. This user code was applied to some detectors used for low-level radioactive wastes monitoring in order to demonstrate the availability of this code. As the result, it was found that the response of anti-Compton spectrometer and the radiation background in a concrete building could be suitably estimated.
Tachibana, Haruo; Yamaguchi, Takenori; Matsuoka, Shungo*; Nemoto, Shintaro*; Kurosawa, Naohiro*
Proceedings of 1st Asian and Oceanic Congress for Radiation Protection (AOCRP-1) (CD-ROM), 7 Pages, 2002/10
An environmental radiation monitoring system in Tokai establishment of JAERI is composed of 14 monitoring posts, 4 monitoring stations, 2 drainage monitors and the monitoring data observation center. These monitoring posts and stations measure the gamma dose rate, and the monitoring stations measure the radioactive air concentration too. Drainage monitors measure the radioactive concentration in drain water. We developed the environmental radiation dose information system used by cellular phone for observing the monitoring data in day and night, working day and holiday at everyplace in Japan. This information system shows us the every minute or every 10 minutes monitoring data table and data trend graph on the cellular phone display. In the emergency situation, this system helps for speedy response such as the notification to the JAERI staffs, starting the emergency environmental monitoring activities, reporting the dose rate and concentration to the national and local authorities, and establishment of the emergency response team in JAERI.
; Ishimori, Yuu; Furuta, Sadaaki;
AOCRP-1, 0 Pages, 2002/00
None
; Tsujimura, Norio;
OP2B-7 P.75, P. 75, 2002/00
None
; Sato, Haruo
P.101(OP8B-4)(2002), 101 Pages, 2002/00
None
Tsujimura, Norio; Momose, Takumaro
PS2-25, 0 Pages, 2002/00
None
Takada, Chie; ; Hozumi, Toshihiko; Hashimoto, Makoto
Proceedings of 1st Asian and Oceanic Congress for Radiation Protection (AOCRP-1) (CD-ROM), p.20 - 24, 2002/00
None
; Takeishi, Minoru
T-6C-3, 0 Pages, 2002/00
None
Kato, Tomoko; ; ; G.Smith*
T-8B-2, 0 Pages, 2002/00
None
Koarashi, Jun; Miyabe, Kenjiro; Mikami, Satoshi
The First Asian and Oceanic Congress for Radiation Protection, 0 Pages, 2002/00
None
Ishida, Junichiro; Takahashi, Keizo; Nomura, Tamotsu
The First Asian and Oceanic Congress for Radiation Protection (AOCRP-1), 0 Pages, 2002/00
None